Environment (Protection) Amendment Rules, 2009
Date of Publication: 18.02.2009
G.S.R.97(E).--In exercise of the powers conferred by Sections 6 and 25 of the Environment (Protection) Act, 1986 (29 of 1986), the Central Government hereby makes the following rules further to amend the Environment (Protection) Rules, 1986, namely:--
1. (1) These rules may be called the Environment (Protection) Amendment Rules, 2009.
(2) They shall come into force on the date of their publication in the Official Gazette.
2. In the Environment (Protection) Rules, 1986, in Schedule I, after serial number 101 and entries relating thereto, the following serial number and entries shall be inserted, namely:--
| ||||||||
S. No. | Industry | Parameter | Standard | |||||
| ||||||||
1 | 2 | 3 | 4 | |||||
| ||||||||
"102 | Refractory Industry | A. Emission Standards |
| |||||
|
| (i) Down Draft Kiln (Fuel Category* | : Coal) limiting concentration (mg/Nm3) | |||||
|
| Particulate matter | small/ medium/ large | 350 | ||||
|
|
| Minimum (metres) | |||||
| Stack height | small | 15 | |||||
|
| medium | 18 | |||||
|
| large | 21 | |||||
| (ii) Other than Down Draft Kiln | |||||||
| (Fuel: Coal) |
| ||||||
|
| Category* | limiting concentration (mg/Nm3) | |||||
| Particulate | small | 300 | |||||
| matter | medium | 200 | |||||
|
| large | 150 | |||||
|
|
| Minimum | |||||
|
|
| (metre) | |||||
| Stack | small | 15 | |||||
| height | medium | 18 | |||||
|
| large | 21 | |||||
| (iii) Box, Tunnel, Down Draft Kiln, etc. (Fuel: Natural Gas/Producer Gas/ LPG or a combination of Fuels/ Furnance Oil as Secondary Fuel) | |||||||
|
| Category* | limiting concentration (mg/Nm3) | |||||
| Particulate matter | Small | 200 | |||||
|
| medium/ | 150 | |||||
|
| large |
| |||||
|
|
| Minimum | |||||
|
|
| (metre) | |||||
| Stack | small | 12 | |||||
| height | medium | 15 | |||||
|
| large | 18 | |||||
| Category* Production (tpa) | |||||||
| small kiln < 15,000 | |||||||
| medium kiln 15,001—50,000 | |||||||
| large kiln above 50,000 | |||||||
| iv. Rotary Kiln (Fuel: Furnance Oil) Category** limiting | |||||||
|
| concentration (mg/Nm3) | ||||||
| Particulate | Small | 200 | |||||
| matter | medium/ | 150 | |||||
|
| large |
| |||||
|
|
| Minimum | |||||
|
|
| (metre) | |||||
| Stack height | small | 35 | |||||
|
| medium | 45 | |||||
|
| large | 60 | |||||
|
| Category** | Production | |||||
|
| Small rotary | (tpd) | |||||
|
| kilin | <50 | |||||
|
| medium rotary |
| |||||
|
| kilin large | 51-100 | |||||
|
| rotary kiln | above 100 | |||||
| ||||||||
Note:--
(i) All values of particulate matter are to be corrected at 6 per cent Carbon Dioxide.
(ii) Fugitive emission shall not exceed 10 mg/m3 from any process or plant.
(iii) Each stack shall be at least 2 metre above the top most point of the building, shed or plant in the industry excluding bucket elevator, mill house and vibrating screen.
(iv) If more than one kiln is connected to single stack, sum of the production capacity of all the kilns would be considered for determining the capacity of the kiln and accordingly depending upon the total capacity, emission standard and stack height would be implemented.
(v) Monitoring of stack shall be carried out at the time of charging and after the completion of charging and average of these two results shall be considered as emission level.
| |||
1 2 | 3 | 4 |
|
| |||
|
| B. Effluent |
|
|
| Standards |
|
|
| Limiting value for | |
|
| concentration (mg/1 | |
|
| except for pH) | |
|
|
|
|
| |||
| Inland Surface Water | Public Sewer | Land for Irrigation |
| |||
pH | 5.5 to 9.0 | 5.5 to 9.0 | 5.5 to 9.0 |
Oil and Grease | 10 | 20 | 10 |
BOD (sic) | 30 | 250 | 100 |
COD | 250 | _ | _ |
Suspended | 100 | 600 | 200 |
Solids |
|
|
|
Phenols | 1.0 | 5.0 | - |
Cyanide as | 02 | 2.0 | 02 |
CN |
|
|
|
Cr(Hexa- | 0.1 | 2.0 | 1.0 |
valent) |
|
|
|
Cr (Total) | 2.0 | 2.0 | 2.0". |
| |||
[F. No. Q-15017/36/2007-CPW]
RAJNEESH DUBE, Jt. Secy.
Note:--The principal rules were published in the Gazette of India vide number S.O.844(E), dated 19th November, 1986 and subsequently amended vide S.O.433 (E), dated 18th April, 1987, S.O.64(E), dated 18th January, 1988, S.O.3 (E), dated 3rd January, 1989, S.O.190 (E), dated 15th March, 1989, G.S.R.913(E), dated the 24th October, 1989, S.O.12 (E), dated the 8th January, 1990, G.S.R.742(E), dated the 30th August, 1990, S.O.23(E), dated the 16 January, 1991, G.S.R.93(E), dated the 21st February, 1991, G.S.R.95(E), dated the 12th February, 1992, G.S.R.329(E), dated the 13th March, 1992, G.S.R.475(E), dated the 5th May, 1992, G.S.R.797(E), dated the 1st October, 1992, G.S.R.386(E), dated the 28th April, 1993, G.S.R.422(E), dated the 19th May, 1993, G.S.R.801(E), dated the 31st December, 1993, G.S.R.176(E), dated the 3rd April, 1996, G.S.R.631(E), dated the 31st October, 1997, G.S.R.504(E), dated the 20th August, 1998, G.S.R.7(E), dated the 2nd January, 1999, G.S.R.682(E), dated the 6th October, 1999, G.S.R.742 (E), dated the 25th September, 2000, G.S.R.72(E), dated the 6th February, 2001, G.S.R.54(E), dated the 22nd January, 2002, G.S.R.371(E), dated the 17th May, 2002, G.S.R.489(E), dated the 9th July, 2002, S.O.1088(E), dated the 11th October, 2002, and G.S.R.849(E), dated the 30th December, 2002, G.S.R.520(E), dated the 1st July, 2003, G.S.R.92(E), dated 29th January, 2004, G.S.R.448(E), dated the 12th July, 2004, Corrigenda G.S.R.520(E), dated the 12th August, 2004, G.S.R.272(E), dated the 5th May, 2005, G.S.R.315(E), dated the 16th May, 2005, G.S.R.546(E), dated the 30th August, 2005, G.S.R.46(E), dated the 3rd February, 2006, G.S.R.464(E) dated the 7th August, 2006, G.S.R.640(E), dated the 16th October, 2006, G.S.R.566(E), dated the 29th August, 2007, G.S.R.704(E), dated the 12th November, 2007, G.S.R.186(E), dated the 18th March, 2008, G.S.R.280(E), dated the 11th April, 2008, G.S.R.344(E), dated the 7th May, 2008, G.S.R.414(E), dated the 30th May, 2008 and G.S.R.481(E), dated the 26th June, 2008, G.S.R.579(E), dated the 6th August, 2008, G.S.R.600(E), dated the 18th August, 2008 and G.S.R.752(E), dated the 24th October, 2008.