Search:
Introduction | About Us | Legal Queries | Forums | Events | Campaigns | FAQ's | Contact Us | Home
CONTENTS OF THIS WEBSITE IS ONLY FOR EDUCATIONAL PURPOSE
You are here: Home Environmental Protection Law/Policy Environment (Protection) Fourth Amendment Rules, 2008
TRADE AND ENVIRONMENT
 
Document Actions

Environment (Protection) Fourth Amendment Rules, 2008

by admin last modified 2008-07-04 16:44

Notification No : GSR414(E),Date : 30.05.2008

In exercise of the powers conferred by Sections 6 and 25 of the Environment (Protection) Act, 1986 (29 of 1986), the Central Government hereby makes the following Rules further to amend the Environment (Protection) Rules, 1986, namely:—

(1) These rules may be called the Environment (Protection) Fourth Amendment Rules, 2008.

(2) They shall come into force on the date of their publication in the Official Gazette.

2. In the Environment (Protection) Rules, 1986,—

(i) in schedule I, after serial number 98 and the entries relating thereto, the following serial number and entries shall be inserted, namely :—

SI. No.

Industry

Parameter

Standard

1

2

3

4

 

 

 

A. Emission Standards*

"99

Sponge Iron Plant (Rotary Kiln)

Particulate matter

Fuel Type Coal gas

Limiting value for concentration 100mg/Nm3 50mg/Nm3

 

 

Carbon Monoxide (VoL/VoL)

coal/gas

1%

 

 

Stack Height**(minimum)

coal/gas

30.0 m

 

 

 

 

 

 

 

Note: —

* Emission shall be normalized at 12% CO2 in stack emission.

** Stack height shall be calculated as H=14.0 Q o3 where Q is emission of Sulphar Dioxide (SO2) in kg./hr. i.e.

 

 

SO2(kg/hr)

up to 12.68

12.69—33.08

33.09—69.06

69.07—127.80

127.81—213.63

Height (metre)

30

40

50

60

70

 

 

(De-dusting unit)

Particulate matter (mg/m3)

Exiting unit

100

New unit

50

 

 

Note:—

(i) Stack attached to de-dusting unit shall have minimum height of 30.0 metre.

(ii) If, De-dusting unit is connected to After Burner Chamber (ABC), emission shall be emitted through common stack (minimum height 30.0 metre) having separate arrangements for emission monitoring for de-dusting unit.

      

 

B. Fugitive Emission Standards

(Rotary Kiln/De- dusting unit)

Particulate matter (ug/m3)

Exiting unit

3000

New unit

2000

 

Note:— (i) the existing industry shall comply with a standard of 2000 ug/m3 after one year from the date of notification,

(ii) Fugitive emission shall be monitored at a distance 10.0 metre from the source of fugitive emission as per following :

 

Area

Raw material handling area

Crusher area

Raw material feed area

Cooler discharge area

Monitoring location

Wagon tippler, Screen area, Transfer

points, Stock bin area

Crushing plant, vibrating screen, transfer

Points

Feeder area, Mixing area, Transfer points

Over size discharge area, Transfer points

 

Product processing area

Intermediate stock bin area, Screening

plant, Magnetic separation unit, Transfer

points, Over size discharge area, Product

separation area, Bagging area

 

Other areas

as specified by State Pollution Control

Board/Pollution Control Committee

 

C. Effluent Standards

 

pH

Total suspended solids

Oil & grease

Chemical oxygen demand

5.5—9.0

100 mg/1

10 mg/1

250 mg/1

 

Note:— (i) All efforts shall be made to reuse and re-circulate the water and to maintain 'Zero discharge'.

(ii) Stormwater drain shall be provided within the premises of the industry so as to avoid mixing with effluent.".

[ F No. Q-15017/95/2000-CPW (Pt.) ]

Sd/-        

( R K Vaish )    

Joint Secretary